Browse Categories

IX-C150 Iwaki/Walchem Advanced Metering Pump


Our Price: $3,237.00

Product Options

Liquid End Options:
Configurations:
Iwaki Pump
IX Series
Item Number: IX-150
  • Motor control adjusts the discharge and suction speeds to meet a full and accurate turndown ratio of 750:1 (150 L/h to 200 mL/h)
  • Maintains accurate flow rates allowing a low cost, mechanically-driven diaphragm pump to achieve a high accuracy of ±1%.
  • Helical gears and return springs reduce power consumption by up to 70% compared to conventional motor-driven mechanical diaphragm metering pumps.
  • Fixed stroke length maintains a high compression ratio in each stroke resulting in fast priming and no air-lock at any flow rate.
  • Controller position can be ordered in 6 positions for operator convenience and ease of use after installation.

Liquid End materials of Construction
Liquid End Code
Pump Head & Fittings
Diaphragm
Valve Balls
Valve Seat
Valve Seals
Gasket
Connections
E-Class
PC
GFRPP
PTFE Bonded to EPDM
CE
FKM
FKM
PTFE
PE Tubing
PE
GFRPP
CE
EPDM
EPDM
VC
PVC
CE
FKM
FKM
VE
PVC
CE
EPDM
EPDM
VF
PVC
PTFE
EPDM
EPDM
VM
M PVC
CE
FKM
FKM
FC
PVDF
CE
PCTFE
PTFE
TC
PVDF
CE
FKM
FKM
HV
PVC
CE
PCTFE
FKM
NPTM
SH
SS
HC
SS
PTFE
1/4" NPTF
VS
PVC
HC/SS
304 SS
EPDM
N/A
VH
PVC
HC
PVC
EPDM
N/A
S6
316 SS
HC
316 SS
-----
N/A
Legend
CE Alumina Ceramic PE Polyethylene SS 316 Stainless Steel
EPDM Ethylene Propylene Diene Monomer PTFE Polytetrafluoroethylene PCTFE Polychlorotrifluoroethylene
FKM Fluoroelastomer PVC Polyvinylchloride(translucent) HC Hastelloy C276
GFRPP Glass Fiber Reinforced Polypropylene PVDF Polyvinylidenefluoride

  • Maximum discharge capacity is rated with clean water at ambient temperature at maximum discharge pressure. Output may
    increase as pressure decreases.
  • Maximum viscosity: 1000 cps (standard pumps - consult factory for higher viscosities)
  • Liquid temperature range: 0 -50°C (TC, TE type), 0-80°C (S6 type). No viscosity change. Non freezing. No slurry.
  • Operating temperature range: 0-50°C (Indoor use only)
  • Operating humidity range: 0-90% RH (Non-condensing in the controller)
  • Maximum dry suction lift is 6.5 ft. (2m).
  • Accuracy is not guaranteed at flows below 0.26GPH (1 LPH) for IX-C150S6 or 0.11GPH (0.4 LPH) for IX-C060S6.
  • Pumps should always be shielded from direct exposure to the elements

Pump Specifications

Size Max Pressure Max Capacity Avg Power Consumption Current Connection Weight
PSI MPa GPH (LPH) W A NPT lbs kg
IX-C060TC 145 1 0.02 - 15.6
(0.08-60)
62W 0.8A 1/2" NPT 23 10.5
IX-C060TE 23 10.5
IX-C060S6 29 13.2
IX-C150TC 58 0.4 0.05-39.6
(0.2-150)
3/4" NPT 23 10.5
IX-C150TE 23 10.5
IX-C150S6 31 14.1

Shopping Cart